Nailor’s commitment to the development of new and existing fire and smoke control technology has resulted in a comprehensive line of premium quality smoke, fire and combination fire/smoke dampers. All Nailor Fire/Smoke Dampers are tested and labeled in accordance with UL 555 and UL 555S. 1 ½ hour or 3 hour rated models available.
taxonomy-1434,taxonomy-1436,taxonomy-1437,taxonomy-1438,taxonomy-1474,taxonomy-1439,taxonomy-1440,taxonomy-1441,taxonomy-1442,taxonomy-1362,taxonomy-1443,taxonomy-1444,taxonomy-1445,taxonomy-1435,taxonomy-1600
Models 1220, 1221, 1222, 1223, 1220-3, 1221-3, 1222-3, and 1223-3
Model Series 1220 and 1220-3 Combination Fire/Smoke Dampers provide the ultimate in fire containment and smoke control for both static and dynamic smoke management systems. They utilize an innovative inter-locking double-skin airfoil blade design that provides a flame and smoke seal, eliminating the need for synthetic blade seals which burn out during fire conditions, and maintains its leakage class up to 2000°F (1093°C) - a feature no other fire/smoke damper in the industry can offer! Ideal for use where building codes require both a fire damper to protect ductwork penetrations in fire separations and a leakage rated damper for use in smoke management systems, it is available with Leakage Class I or II at 250°F (121°C) or 350°F (177°C). Available at standard dynamic velocity/pressure rating of 2000 fpm @ 4" w.g. (10 m/s @ 1 kPa), UL tested with extended ratings up to 4000 fpm (20 m/s) and 8" w.g. (2 kPa). Model Series 1220 and 1220-3 have been specially designed and tested to provide premium performance and are AMCA licensed. Qualified for installation with airflow in either direction and inverted mounting.
Models 1220SS, 1221SS, 1222SS, 1223SS, 1221SS-3, 1222SS-3, and 1223SS-3
Model Series 1220SS and 1220SS-3 Combination Fire/Smoke Dampers are ideal for high humidity, mildly corrosive environment applications where building codes require both a fire damper for the protection of ductwork penetrations in walls and a leakage rated damper for operational smoke control on static or dynamic smoke management systems. Features include an airfoil blade, low pressure drop frame design, and maintenance free concealed blade linkage for superb air performance and minimal turbulence and noise. Optional Type 316 Stainless Steel construction is available for more severe environment applications.
Models 1221-OW, and 1221-DOW
Models 1221-DOW and 1221-OW are "out of wall" high performance combination fire/smoke damper specifically designed for applications where the damper cannot be installed within the plane of the wall or floor. They features Nailor’s unique inter-locking double skin airfoil blade design that eliminates combustible seals and provides flame and smoke seal under fire conditions at temperatures up to 2000°F (1093°C)! Model 1221-DOW is designed for ducted through penetrations where as Model 1221-OW is designed for applications that terminate at a grille and provide easy actuator access.
Models 1221-OWM and 1221-DOWM
This "3-in-1" damper provides volume control via an electric or pneumatic modulating actuator as well as fire and smoke control for "out of wall" applications.
Model 1221G
Model 1221G is a high performance combination fire/smoke damper specifically designed for supply or return ducts that terminate at a grille. The factory sleeve with unique 3/4" (19) grille mounting tabs simplifies installation, saves on field labor and eliminates the requirements for unsightly front retaining angles which commonly protrude from behind the grille. A steel grille installs over and completely hides the mounting tabs. The damper is offset in the sleeve to accommodate a single or double deflection supply air grille, single deflection supply air register or a return air grille or register.
Models 1221C-1, 1221C-2, 1221C-3, 1221C-4
Models 1221C-1, 1221C-2 and 1221C-4 Airfoil Blade Tunnel Corridor Combination Fire/Smoke Dampers are for use where ductwork penetrates the ceiling of an interior corridor of a building, creating a horizontal opening that requires protection. Model 1221C-1 and 1221C-4 are suitable for use with a steel grille or diffuser when the duct terminates at the ceiling. 1221C-4 includes grille side access to the actuator. Model 1221C-2 is suitable for use when the duct is required to continue down past the ceiling level. Each unit is supplied factory mounted in a suitable sleeve complete with upper retaining angles. Model 1221C-3 is both a 1 hr. rated Corridor Damper for use in corridor ceilings and a standard 1 1/2 hr. rated Combination Fire/Smoke Damper for use in walls and floors. The dual rating makes it ideal for stocking as the unit can be supplied when either type of damper is required by the local customer.
Model 1220M(-3), 1221M(-3), 1222M(-3), and 1223M(-3)
Model Series 1220M and 1220M-3 "3-in-1" Modulating Fire/Smoke Dampers have been engineered to provide premium containment in fire and smoke conditions. The addition of volume control using a modulating actuator eliminates the need and cost of a separate control damper.
Models 1221VB, 1222VB, and 1223VB
Model 1221VB is a high performance combination fire/smoke damper that provides superior protection and versatility. The vertical blade configuration allows for the actuator to be mounted below the damper and is ideal for applications where bottom access is desired or where there is not enough space for a side mounted actuator.
Model 1270, 1271, 1272, and 1273
Model Series 1270 combination fire/smoke dampers, with sturdy veegroove style blades and a rugged mitered corner hat channel frame design that virtually eliminates racking, provides 1 1/2 hour UL labeled fire protection suitable for use where ductwork penetrates a wall or floor with a fire resistance rating of 2 hours or less. The 1270 Series is UL tested and labeled for use as a Class I or II Leakage Rated Damper for smoke control applications in both static or dynamic HVAC system designs. Available with factory fitted sleeve (Model 1271), and a variety of actuators and options to suit each application, the 1270 series is a versatile and economical performer suitable for most commercial applications.
Model 1271G
Model 1271G is a combination fire/smoke damper specifically designed for supply or return ducts that terminate at a grille. The sleeve with unique 3/4" (19) grille mounting tabs simplifies installation, saves on field labor and eliminates the requirements for unsightly front retaining angles which commonly protrude from behind the grille. A steel grille installs over and completely hides the mounting tabs. The damper is offset in the sleeve to accommodate a single or double deflection supply air grille, single deflection supply air register or a return air grille or register.
Models 1271C-1, 1271C-2, and 1271C-3
Models 1271C-1 and 1271C-2 Tunnel Corridor Combination Fire/Smoke Dampers are for use where ductwork penetrates the ceiling of an interior corridor of a building, creating a horizontal opening that requires protection. Model 1271C-1 is suitable for use with a steel grille or diffuser when the duct terminates at the ceiling. Model 1271C-2 is suitable for use when the duct is required to continue down past the ceiling level. Each unit is supplied factory mounted in a suitable sleeve complete with upper retaining angles. Model 1271C-3 is both a 1 hr. rated corridor damper for use in corridor ceilings and a standard 1 1/2 hr. rated combination fire/smoke damper for use in walls and floors. The dual rating makes it ideal for stocking as the unit can be supplied when either type of damper is required by the local customer.
Models 1290FS and 1290FS-SS
Nailor’s True Round Combination Fire/Smoke Damper, Model 1290FS, is ideal for round duct applications where building codes require both a fire damper for the protection of ductwork penetrations in walls or floor that have a fire resistance rating of up to 2 hours and a leakage rated damper for operational smoke control on static or dynamic smoke management systems. Model 1290FS is an economical round combination fire/smoke damper designed and qualified for round ductwork passing through metal drywall partitions or masonry walls. Features of the damper include a sturdy beaded casing for superior rigidity and factory supplied retaining plates for fast, secure installation. The 1290FS offers the lowest leakage class available, Leakage Class I or II at 250°F (121°C) or 350°F (177°C), and is approved for vertical or horizontal installation.