Content Container Model D0110DOW, D0110GOW, D0120GOW are "out of wall or floor" integral sleeve dynamic curtain type fire dampers. Model D0110GOW and D0120GOW are designed for supply or return ducts that terminate at a grille or register. Model D0110DOW is designed for through penetrations (ductwork connected to both sides) where the damper cannot be installed within the plane of the wall. UL approved for use where local building codes require the protection of HVAC ductwork penetrations in walls, partitions or floors that have a fire resistance rating of up to 2 hours. These dampers are particularly suited for use in common steel stud drywall partition designs as narrow as 3 1/2" (89), where a traditional "within the plane of the wall" fire damper installation is not possible. Models D0110DOW - Out of Wall, Ducted D0110GOW - Out of Wall, Grille Mount D0120GOW - Type B, Out of Wall, Grille Mount Submittals All Submittals Combined Individual Submittals D0110DOW • Curtain Fire Damper • Dynamic • 1 ½ Hour • Out of Wall, Ducted D0110GOW • Curtain Fire Damper • Dynamic • 1 ½ Hour • Out of Wall, Grille Mount D0120GOW • Curtain Fire Damper • Dynamic • 1 ½ Hour • Out of Wall, Grille Mount • Type B Options and Accessories ETL • Electro Thermal Link • For Curtain Fire Dampers Quick-Set Retaining Angles for all Sleeved Fire and Combination Fire/Smoke Dampers Control Sequence Performance Data Finish IOM (D)0100, 0200, 0300, (D)0500 Series • Operation & Maintenance Procedures D0110D0W and 0110D0W • Curtain Fire Damper • 1 ½ Hour • Out of Wall, Ducted • Installation Instructions D0110GOW, 0110GOW • Curtain Fire Damper • 1 ½ Hour • Out of Wall For Grilles • Installation Instructions D0120GOW, 0120GOW • Curtain Fire Damper • 1 ½ Hour • Out of Wall • For Grille/Register • Installation Instructions ETL • Electro-Thermal Link • Installation Instructions Field Extension of Factory Sleeves • Fire & Combination Fire/Smoke Damper • Installation Instructions Fire Resistant Cavity Shaft Wall Partitions • Fire & Fire/Smoke Dampers • Installation Instructions Fire Resistant Ventilation Duct Assembly for Fire Dampers and Combination Fire/Smoke Dampers Optional Sealing of Fire Dampers & Fire/Smoke Dampers in Wall/Partition or Floor Openings • Installation Instructions Single Side Retaining Angles • Fire & Fire/Smoke Dampers • 1 ½ Hour only • Installation Instructions Sleeve Trimming Instructions Steel & Wood Stud Framing in Drywall Partitions • Fire & Fire/Smoke Dampers • Installation Instructions Miami-Dade NOA Specifications Catalog Literature