Content Container Model series 0500 (steel) and 0500SS (stainless steel), Standard Frame Static Curtain Fire Dampers, for use in static "fans off" systems where the HVAC system shuts down in the event of a fire, are UL approved to provide protection of HVAC ductwork penetrations in walls, partitions or floors that have a fire resistance rating of 4 hours or less. The 0500V/H Series features corrosion resistant steel frame and blades for performance that will last and a choice of transition styles and factory installed sleeves to suit duct size, making installation fast and simple. Models Stainless Steel 0510SS - Type A 0520SS - Type B 0530SS - Type C Galvanized 0510V - Type A • Vertical 0510H - Type A • Horizontal 0520V - Type B • Vertical 0520H - Type B • Horizontal 0530V - Type C • Vertical 0530H - Type C • Horizontal Submittals All Submittals Combined Individual Submittals 0100, 0500 Series • Standard Frame Curtain Fire Damper Sizing Charts • Imperial 0100, 0500 Series • Standard Frame Curtain Fire Damper Sizing Charts • Metric 0510SS • Curtain Fire Damper • 3 hour • Static • Type A • Stainless Steel 0510V, 0510H • Curtain Fire Damper • 3 hour • Static • Type A 0520SS • Curtain Fire Damper • 3 hour • Static • Type B • Stainless Steel 0520V, 0520H • Curtain Fire Damper • 3 hour • Static • Type B 0530SS • Curtain Fire Damper • 3 hour • Static • Type C - CR, CO • Stainless Steel 0530SS • Curtain Fire Damper • 3 hour • Static • Type C - CSR • Stainless Steel 0530V, 0530H • Curtain Fire Damper • 3 hour • Static • Type C - CR, CO 0530V, 0530H • Curtain Fire Damper • 3 hour • Static • Type C - CSR Options and Accessories Curtain Fire Dampers • Sleeve Types ETL • Electro Thermal Link • For Curtain Fire Dampers PTR • Pull Tab Release • for Horizontal Mounted Fire Dampers Quick-Set Retaining Angles for all Sleeved Fire and Combination Fire/Smoke Dampers Performance Data 0520, 0530, 0540 • Free Area • Pressure Drop IOM (D)0100, 0200, 0300, (D)0500 Series • Operation & Maintenance Procedures (D)0100, 0300, (D)0500 Series • Curtain Fire Damper • Installation Instructions (D)0100, 0300, (D)0500 Series • Curtain Fire Damper • Installation Instructions (French Version) 0100, 0500 Series • Standard Frame Curtain Fire Damper Sizing Chart • Imperial Concrete Floor with Steel Deck • Fire & Fire/Smoke Dampers • Installation Instructions Curtain Fire Dampers • Sleeve Types • Installation Instructions ETL • Electro-Thermal Link • Installation Instructions Field Extension of Factory Sleeves • Fire & Combination Fire/Smoke Damper • Installation Instructions Fire Resistant Cavity Shaft Wall Partitions • Fire & Fire/Smoke Dampers • Installation Instructions Fire Resistant Ventilation Duct Assembly for Fire Dampers and Combination Fire/Smoke Dampers Flanged Type Alternate Breakaway Connections • Installation Instructions Optional Sealing of Fire Dampers & Fire/Smoke Dampers in Wall/Partition or Floor Openings • Installation Instructions PTR • Pull Tab Release QS1, QS2 • 'Quick - Set' Retaining Angles • Fire & Fire/Smoke Dampers Single Side Retaining Angles • Fire & Fire/Smoke Dampers • 1 ½ Hour only • Installation Instructions Sleeve Trimming Instructions Steel & Wood Stud Framing in Drywall Partitions • Fire & Fire/Smoke Dampers • Installation Instructions Steel Mullion for Fire Dampers in Oversized Wall Openings • Installation Instructions TDC/TDF Proprietary Flange System Breakaway Connections • Installation Instructions Catalog Literature Curtain Fire Dampers