Content Container Designed for control of hot or neutral and cold air. Variable volume with or without mixing or constant volume applications. Models With Compact Mixing Attenuator D3230HQ - w/ Dissipative Silencer • Hospital Grade • Super Quiet D3230 - DDC Controls P3230 - Pneumatic Controls "BlendMaster" with High Efficiency Mixing Attenuator D3240 - DDC Controls P3240 - Pneumatic Controls Without Mixing Attenuator D3210 - DDC Controls P3210 - Pneumatic Controls Submittals All Submittals Combined Individual Submittals D3210, • Digital Electronic Controls • No Mixing D3230 • Digital Controls • w/ Compact Mixing Attenuator D3230HQ • Dual Duct Terminal Unit w/Compact Mixing Attenuation • w/ Dissipative Silencer • Hospital Grade • Super Quiet D3240 • Digital • w/ "BlendMaster" High Efficiency Mixing P3210 • Pneumatic Controls • No Mixing P3230 • Pneumatic Controls • Compact Mixing Attenuator P3240 • Pneumatic Controls • "BlendMaster" High Efficiency Mixing Options and Accessories Liner Option • Dual Density Liner Option • Fiberglass Dual Density Liner Option • Solid Metal Control Sequence EZvav Digital Controls • Control Sequence N200 EZvav Digital Controls • Control Sequence N201 Index for Pneumatic Control Package Sequences Pneumatic • Mixing at Minimum • Control Package DP2-101 • Direct Acting • OR • 3C • Cold and Hot Deck Normally Open Pneumatic • Mixing at Minimum • Control Package DP2-102 • Direct Acting • OR • 3C • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • Mixing at Minimum • Control Package DP2-103 • Direct Acting • OR • 3C • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • Mixing at Minimum • Control Package DP2-104 • Direct Acting • OR • 3C • Cold and Hot Deck Normally Closed Pneumatic • Mixing at Minimum • Control Package DP2-105 • Direct Acting • OL • 3C • Cold and Hot Deck Normally Open Pneumatic • Mixing at Minimum • Control Package DP2-106 • Direct Acting • OL • 3C • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • Mixing at Minimum • Control Package DP2-107 • Direct Acting • OL • 3C • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • Mixing at Minimum • Control Package DP2-108 • Direct Acting • OL • 3C • Cold and Hot Deck Normally Closed Pneumatic • Mixing at Minimum • Control Package DP2-109 • Reverse Acting • OR • 3C • Cold and Hot Deck Normally Open Pneumatic • Mixing at Minimum • Control Package DP2-110 • Reverse Acting • OR • 3C • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • Mixing at Minimum • Control Package DP2-111 • Reverse Acting • OR • 3C • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • Mixing at Minimum • Control Package DP2-112 • Reverse Acting • OR • 3C • Cold and Hot Deck Normally Closed Pneumatic • Mixing at Minimum • Control Package DP2-113 • Reverse Acting • OL • 3C • Cold and Hot Deck Normally Open Pneumatic • Mixing at Minimum • Control Package DP2-114 • Reverse Acting • OL • 3C • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • Mixing at Minimum • Control Package DP2-115 • Reverse Acting • OL • 3C • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • Mixing at Minimum • Control Package DP2-116 • Reverse Acting • OL • 3C • Cold and Hot Deck Normally Closed Pneumatic • Mixing at Minimum • Control Package DP2-119 • Direct Acting • OR • 3B • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • Mixing at Minimum • Control Package DP2-123 • Direct Acting • OL • 3B • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • Mixing Hot and Cold • Control Package DP3-101 • Direct Acting • OR • 3C • Cold and Hot Deck Normally Open Pneumatic • Mixing Hot and Cold • Control Package DP3-102 • Direct Acting • OR • 3C • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • Mixing Hot and Cold • Control Package DP3-103 • Direct Acting • OR • 3C • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • Mixing Hot and Cold • Control Package DP3-104 • Direct Acting • OR • 3C • Cold and Hot Deck Normally Closed Pneumatic • Mixing Hot and Cold • Control Package DP3-105 • Direct Acting • OL • 3C • Cold and Hot Deck Normally Open Pneumatic • Mixing Hot and Cold • Control Package DP3-106 • Direct Acting • OL • 3C • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • Mixing Hot and Cold • Control Package DP3-107 • Direct Acting • OL • 3C • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • Mixing Hot and Cold • Control Package DP3-108 • Direct Acting • OL • 3C • Cold and Hot Deck Normally Closed Pneumatic • Mixing Hot and Cold • Control Package DP3-109 • Reverse Acting • OR • 3C • Cold and Hot Deck Normally Open Pneumatic • Mixing Hot and Cold • Control Package DP3-110 • Reverse Acting • OR • 3C • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • Mixing Hot and Cold • Control Package DP3-111 • Reverse Acting • OR • 3C • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • Mixing Hot and Cold • Control Package DP3-112 • Reverse Acting • OR • 3C • Cold and Hot Deck Normally Closed Pneumatic • Mixing Hot and Cold • Control Package DP3-113 • Reverse Acting • OL • 3C • Cold and Hot Deck Normally Open Pneumatic • Mixing Hot and Cold • Control Package DP3-114 • Reverse Acting • OL • 3C • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • Mixing Hot and Cold • Control Package DP3-115 • Reverse Acting • OL • 3C • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • Mixing Hot and Cold • Control Package DP3-116 • Reverse Acting • OL • 3C • Cold and Hot Deck Normally Closed Pneumatic • Mixing Hot and Cold • Control Package DP3-120 • Direct Acting • OR • 3B • Cold and Hot Deck Normally Closed Pneumatic • No Mixing • Control Package DP1-101 Direct Acting • OR • 3A • Cold and Hot Deck Normally Open Pneumatic • No Mixing • Control Package DP1-102 • Direct Acting • OR • 3A • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • No Mixing • Control Package DP1-103 • Direct Acting • OR • 3A • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • No Mixing • Control Package DP1-104 • Direct Acting • OR • 3A • Cold and Hot Deck Normally Closed Pneumatic • No Mixing • Control Package DP1-105 • Direct Acting • OL • 3A • Cold and Hot Deck Normally Open Pneumatic • No Mixing • Control Package DP1-106 • Direct Acting • OL • 3A • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • No Mixing • Control Package DP1-107 • Direct Acting • OL • 3A • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • No Mixing • Control Package DP1-108 • Direct Acting • OL • 3A • Cold and Hot Deck Normally Closed Pneumatic • No Mixing • Control Package DP1-109 • Reverse Acting • OR • 3A • Cold and Hot Deck Normally Open Pneumatic • No Mixing • Control Package DP1-110 • Reverse Acting • OR • 3A • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • No Mixing • Control Package DP1-111 • Reverse Acting • OR • 3A • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • No Mixing • Control Package DP1-112 • Reverse Acting • OR • 3A • Cold and Hot Deck Normally Closed Pneumatic • No Mixing • Control Package DP1-113 • Reverse Acting • OL • 3A • Cold and Hot Deck Normally Open Pneumatic • No Mixing • Control Package DP1-114 • Reverse Acting • OL • 3A • Cold Deck Normally Open • Hot Deck Normally Closed Pneumatic • No Mixing • Control Package DP1-115 • Reverse Acting • OL • 3A • Cold Deck Normally Closed • Hot Deck Normally Open Pneumatic • No Mixing • Control Package DP1-116 • Reverse Acting • OL • 3A • Cold and Hot Deck Normally Closed Performance Data 3200 Series • Performance Data Explanation • Sound Power vs. NC 3210 • Dual Duct Terminal Units • AHRI Certification Rating Points 3210 • Dual Duct Terminal Units • Discharge Sound Power Levels 3210 • Dual Duct Terminal Units • NC Level Application Guide 3210 • Dual Duct Terminal Units • Radiated Sound Power Levels 3210 • Dual Duct Terminal Units • Recommended Airflow Ranges 3230 • Dual Duct Terminal Units • AHRI Certification Rating Points 3230 • Dual Duct Terminal Units • Discharge Sound Power Levels 3230 • Dual Duct Terminal Units • NC Level Application Guide 3230 • Dual Duct Terminal Units • Radiated Sound Power Levels 3230 • Dual Duct Terminal Units • Recommended Airflow Ranges 3230HQ • Dual Duct Terminal Units • Dissipative Silencer • AHRI Certification 3230HQ • Dual Duct Terminal Units • Dissipative Silencer • Discharge Sound Power Levels 3230HQ • Dual Duct Terminal Units • Dissipative Silencer • Radiated Sound Power Levels 3230HQ • Dual Duct Terminal Units • Dissipativee Silencer • NC Level Application Guide 3240 • Dual Duct Terminal Units • AHRI Certification Rating Points 3240 • Dual Duct Terminal Units • Discharge Sound Power Levels 3240 • Dual Duct Terminal Units • NC Level Application Guide 3240 • Dual Duct Terminal Units • Radiated Sound Power Levels 3240 • Dual Duct Terminal Units • Recommended Airflow Ranges IOM EZvav Digital Controls • Quick Start Installation Guide 3200 • Dual Duct Terminal Units • Installation Instructions Airflow Sensor K-Factors for Terminal Units EZvav Digital Controls • Installation Instructions Specifications DDTU • Dual Duct Terminal Unit • Word Document [.docx] Catalog